COBRA

FUNDUS CAMERA

Cobra HD is a non-mydriatic digital fundus camera that comprises all the functions required for a rapid screening of the status of the retina. Cobra uses an innovative optical system that can provide high quality images of the ocular fundus. With its ergonomic design Cobra provides a clear and detailed image of the ocular fundus with a field of vision of up to 50 degrees. Cobra uses a minimum flash exposure, allowing a fast and detailed acquisition of the fundus and minimizing the discomfort for the patient. Cobra HD shares the use of the CCD high-resolution sensor (5 megapixel) for the alignment of the pa- tient (with IR illumination) and the capture of retinal images (with a white light flash and IR LEDs).

The USB connection between the device and the PC enables a fast and easy transfer of the images. Patient data is saved in the Phoenix patient management software system in a stand-alone configuration or in a network: it is also possible to activate a DICOM connection to transfer images. Ergonomically designed Cobra provides clear and detailed display of the entire fundus image at true 60 field of view. The system offers retinal photography with minimum flash exposure allowing quick and efficient fundus photography, thereby minimizing patient discomfort. Cobra shares the use of the high resolution CCD camera (5 MegaPixel) for alignment (IR illumination) and capture (White light flash). New features: - wavelengths splitter - MOSAIC function - Mebomiam Glands Analysis - AVR tool - Overlap with RETIMAX

MULTIPLE WAVE-LENGTH IMAGES

Multiple wave-length images can be displayed on one screen: the original image, infrared image, red-free image, as well the choroidal,  vascular  and nerve fiber  image.  

CUP TO DISK MEASUREMENT

The measurement of the Cup to Disk ratio is easily acheived using the built in measurement tools that are available in the Phoenix software platform for the detection of glaucomatous disease.  

MOSAIC FUNCTION

Cobra HD allows the acquisition of multiple images, to create a panoramic image of the  peripheral retinal areas.  

MGD ANALYSIS MODULE (meibography)

Cobra HD includes a module for the analysis of the Meibomian Glands (MGD). Using Pheonix software, the glands structure and health can be analysed.  

INTEGRATION TOOL WITH ERG TEST*

The image of the retinal fundus provided by COBRA can be combined with the multifocal ERG test, performed with the RETIMAX device. This new module provides a precise indication of the functionality of every analyzed retinal area; it is very useful for the diagnosis and the follow-up of Macular Degeneration as well as degenerative hereditary retinal diseases. *optional module  

AVR EVALUATION MODULE (optional))

The AVR tool measures the relationship between the branch arteriolar-venous diameter. A low relationship between the dimension of the vessels, may  be predictive of cardiovascular problems in adult patients.  

TECHNICAL DATA

USB 3.0
Power supply: external power source 24 VCC
In: 100-240Vac - 50/60Hz - 0.9-05A - Out: 24Vdc - 40W
Power net cable: IEC C14 plug
Dimensions (HxWxD): 420mm x 315mm x 255mm
Weight: 6Kg
Chin rest movement: 70mm ± 1mm
Minimum height of the chin cup from table: 23cm
Base movement (xyz): 105 x 110 x 30mm
Working distance: 20mm
LIGHT SOURCES  
Auxiliary IR Led @850nm
White flash Led @450-650nm
   
RETINOGRAPHY  
Spherical  correction from -20D to +15D (through handle placed on the optic head)
Image resolution 2448 x 2051 (5MPixel)
Visual field 50° x 45°
Minimum pupil size 2.5mm
Compatibility with standard UNI EN ISO 10940:2009, DICOM v3 (IHE integrati on profi le EYECARE
Workfl ow)
REQUISITI MINIMI DI SISTEMA  
PC: 4 GB RAM - Scheda Video 1 GB RAM (non condivisa) risoluzione 1024 x 768 pixels - USB 3.0 type A Sistema operati vo: Windows XP, Windows 7 e Windows 10 (32/64 bit).